Meriam’s M2110F Smart Flow Gauge is a
microprocessor-based pressure sensing
device with algorithms to calculate flow.
The gauge provides laminar flow element,
Accutube and Orifice Plate flow
measurements. Three configurations are
available: Battery, SetPoint, and Current
Loop models.
All models are programmable through the
front keypad. The user’s program
information is stored in non-volatile
memory, and is retained when the power
to the gauge is removed. SetPoint and
Current Loop models can also be
programmed through the RS-232 serial
communication connection.
The Battery model is powered by its internal lithium batteries. This model does not provide any
outputs or RS-232 communications.
SetPoint and Current Loop models have outputs that can be used for control or indicating
functions. Both models also have RS-232 communications capability. In addition to configuring
the gauge, the RS-232 port can be used to monitor and log the measured flow data and output
status. It can also be used as part of a control system with digital capabilities.
The SetPoint model provides two relay outputs. These relays can be connected in normally open
or normally closed configurations for fail-safe operation. SetPoint detection can be set from 0 to
+120% of the full scale flow range and is powered by 115VAC, 230 VAC, or 24VDC.
The Current Loop model provides a 4 to 20 mA output, and is intended to be used as a flow
transmitter on a three or four wire loop. Zero and span are set through user-programmable
registers, from 0 to +120% of the full scale flow range. The Current Loop model is powered by
24VDC only.
M2110F SMART FLOW GAUGE
OPERATING INSTRUCTIONS
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - OPERATING INSTRUCTIONS

9R142 Dated 2/1/11 1 Meriam’s M2110F Smart Flow Gauge is a microprocessor-based pressure sensing device with algorithms to calculate flow.

Page 2 - Table of Contents

10 4.2.4 PRGM or ENTER Mode of Operation PRGM Document Symbol: (PRGM/Enter→) Measure Mode Selects Program Mode, which allows access to the progra

Page 3

11 5 PROGRAMMING IMPORTANT: Programmable registers above P0 cannot be adjusted unless the correct lockout code is entered or the lockout code is dis

Page 4 - 1 OVERVIEW

12 5.1 PROGRAMMABLE REGISTER LIST All M2110F Flow Gauges have programmable registers that allow the gauge to be configured to fit the flow measureme

Page 5 - 2 Safety Warnings

13 6 STARTUP REQUIREMENTS The initial power up of the M2110F Flow Gauge will require register configuration to match the requirements of the applic

Page 6

14 6.4 Low Flow CutOff 1. Access P4: Low Flow CutOff 2. Sets a flow level for which the readout LCD and serial port devices will display a clamped

Page 7 - 4 FRONT PANEL

15 7.1.2 RE-ZEROING THE GAUGE / OUTPUTS ENABLED (P5=1, 2 or 3): 1. Gauge in MEASURE MODE with zero flow through primary element 2. Press the UP A

Page 8

16 8 ENGINEERING UNITS The Engineering units are modified as part of the P9: B-Coefficient/Flow Constant editing process. The purpose of this dep

Page 9

17 9 PROGRAMMABLE REGISTERS 9.1 P0 – LOCKOUT CODE This feature provides security in the Smart Gauge. It is designed to prevent unauthorized person

Page 10

18 9.3 P2- DISPLAY DAMP RATE The Smart Gauge has a selectable damping rate, which is used to filter the display. The damp rate setting is approximat

Page 11 - 5 PROGRAMMING

19 9.5 P4 – LOW FLOW CUTOFF This register is used by the gauge to set a minimum active displayable flow value. Once the flow measurement falls belo

Page 12

2 Table of Contents 1 OVERVIEW...

Page 13 - 6 STARTUP REQUIREMENTS

20 9.6 P5 – SETPOINT OPTIONS This register defines the output action for SetPoint and Current Loop models. Note that if an output is disabled by th

Page 14 - 7 ZERO REFERENCE

21 9.7.3 Data Entry These programmable registers are entered in the current Engineering Unit used by the gauge, which are illuminated during edit of

Page 15

22 9.8 P8 – DEADBAND This register is found on the SetPoint model only. The deadband can be set to 0 (disabled), 0.1, 0.2, 0.5, 1, 2, 5 and 10% of f

Page 16 - 8 ENGINEERING UNITS

23 9.9 P9 – FLOW MEASUREMENT B-COEFFICIENT The Flow Gauge calculates flow based on the differential pressure that develops across the primary elemen

Page 17 - 9 PROGRAMMABLE REGISTERS

24 4. The display shows the exponent value for P9. Press the UP or DOWN ARROWS to change the exponent digit. • Press PRGM/ENTER to enter the digit,

Page 18

25 GAUGE IN MEASURE MODE 1. Press PRGM/ENTER to access P0 prompt 2. If lockout is in-active prompt will be P0 • Increment P# using UP ARROW until P

Page 19

26 11 SERIAL PORT SERVICE The M2110F Smart Flow Gauge SetPoint and Current Loop models provide RS-232C communication capability. To use the serial

Page 20

27 While the serial port is transferring data, the other functions of the gauge are paused to allow this task to complete. In this paused state, the

Page 21

28 12 ERROR CODES All Smart Gauge models have an error/message feature to inform the operator of problems with the operation or programming of the g

Page 22

29 13 SUPPLEMENTARY INFORMATION 13.1 Application Example 13.1.1 Laminar flow element Primary Element: Laminar Flow Element (LFE) Model 50

Page 23

3 9.3 P2- DISPLAY DAMP RATE ...18 9.4

Page 24

30 14 INSTALLATION Differential pressure sensors have two pressure connections on the back of the gauge. The diagram below shows the correct connect

Page 25 - 10 REGISTER SECURITY

31 14.1 ELECTRICAL CONNECTIONS Setpoint models come with a terminal block interface while the Current Loop model comes with an eight-pin circular co

Page 26 - 11 SERIAL PORT SERVICE

32 14.2 CURRENT LOOP MODEL WIRING 14.2.1 Current Loop Model Interface Connections The Current Loop Model connections are made through the supplied i

Page 27

33 3.60 in. (92mm) 3.60 in. (92mm) PANEL MOUNT CUTOUT 14.3 OUTLINE DIMENSIONS 14.3.1 Panel Mounting 1. Make a ¼ DIN panel c

Page 28 - 12 ERROR CODES

34 15 PRODUCT SPECIFICATIONS TYPE & RANGE: DN: Differential Non-Isolated CI: Compound Isolated GI: Gauge Isolated AI: Absolute Isolated D

Page 29

35 Range Limits and Indication Sensor Hard Soft Certified Soft Hard Type Under Under Range Over Over Range Range (F.S.) Range Ra

Page 30 - 14 INSTALLATION

36 16 Service and Calibration In the event an M2110 requires service or needs to be returned for factory recertification, battery replacement, or re-

Page 31

4 1 OVERVIEW The Meriam Instrument M2110F Gauge is a microprocessor based flow-sensing device that can be used in conjunction with a primary flow el

Page 32

5 2 Safety Warnings The table below defines the safety symbols, signal words and corresponding safety messages used in the manual to identify potenti

Page 33

6 3 Certification / Safety / Warnings Fire/Explosion Hazard. This instrument is not intrinsically safe. DO NOT use or service in areas that may con

Page 34 - Sensor Ranges

7 4 FRONT PANEL Warning All settings must only be entered by qualified personnel, paying particular attention to the safety and precautionary warni

Page 35 - Range Limits and Indication

8 4.1.2 Display Refresh Rate The M2110F Flow gauge converts signal data from the differential pressure sensor at a rate of ten conversions per second

Page 36 - 16 Service and Calibration

9 4.2.2 ENGINEERING UNITS or UP ARROW Mode of Operation ENGUNITS Document Symbol: (Up↑) Measure Mode No function in this mode. Will generate e